Three selectors, built as working prototypes. The first sits on a general page and routes a
visitor to the right product across the whole catalog. The second sits on the VAULT® page and
routes to a specific configuration — Standard, Pre-Engineered, or Custom. The third sits on the
ENTRYPORT™ page and routes to a standard Wall Guard size or the custom team, returning RPH
Exit Seals™ part numbers along the way.
Updated following the engineering review call. Terminology now uses Core Designs
as the umbrella for the ENTRYPORT™, VAULT® and CYCLONE® lines; inside a line, products carry
their own names — VAULT® Giga, VAULT® Mega and so on. The pre-engineered tier is no longer
named publicly. Please review the questions, the answer options, and the outcome each path
produces. Remaining open items are listed at the end.
Prepared for RPH · Prototype review · August 2026
Selector one
Which product is right for your project?
Rebuilt around the goal-based structure Jenna proposed. One to three questions, nine possible
products. Two principles shape it: the four goals sit parallel to each other rather than
nested, and a certification requirement decides which product leads rather than which
products survive.
Question Product Answer path Skips the next question
Why the wind question is gone. The earlier version asked “are there wind
requirements?” and sent yes to CYCLONE®, no to VAULT®. That implied VAULT® has no wind rating.
It does — the AW / AWI data sheet lists Florida Building Code FL47590.1-R0, TAS 201, 202 and
203, and ASTM E1886 and E1996, which is hurricane pressure cycling and windborne debris impact.
The real distinction is that CYCLONE® is additionally tested to ICC 500 and FEMA P-361 for
250 mph with separate missile impact testing, which is occupant protection inside a storm
shelter rather than envelope protection in a hurricane zone. A specifier on a Gulf Coast warehouse who answered
“yes” was being routed away from the product built for their job.
Note Penetrant type is asked before the specification driver because it is the only
answer that settles the question outright: square and rectangular ductwork is VAULT®-only,
louvers and air intakes are CSH-only, and a specifier always knows which they have. Those two
answers skip the second question entirely.
Drainage, venting and egress sit as sibling goals rather than beneath a “no” to roof
protection. A roof drain, a vent through roof and a roof hatch are all penetrations through
the roof, so a visitor who answers a roof question first would never reach them.
Four corrections from the engineering review
What changed
Why
The vent option now reads “venting for lavatories, urinals or water closets”
The CYCLONE® Vent Through Roof is a sanitary vent — a Studor vent taken through the
roof rather than left in the wall. It does not handle equipment exhaust, high heat or
high velocity. The previous wording said “plumbing vent or exhaust,” which would have
routed mechanical engineers to a product that cannot do the job.
The storm shelter result no longer offers an alternative
VAULT® should not be specified for storm shelter use, and tornado and hurricane
ratings are not interchangeable — one is cyclical wind loading, the other static, and
they are separately tested. Every other path keeps its alternative.
Some second products are now shown as pairings, not alternatives
The ENTRYPORT™ Wall Guard is a sealing device and the CYCLONE® Wall Shroud is a
protection device; projects often fit the plate and cover it with a shroud. Primary
and overflow roof drains are a required pair — the roof needs both. Presenting either
as “also worth considering” understated the relationship.
Missile impact and wind rating are now two separate claims
The missile is fired at 100 mph horizontally and 67 mph vertically; the wind rating to
250 mph is separate testing. The single “250+ mph with missile impact” chip conflated
them.
For the October 16 legal review. The corrected certification wording —
missile impact at 100 mph horizontal and 67 mph vertical, wind rated to 250 mph, as two
distinct claims — should go into the legal packet rather than waiting for a later pass. These
figures appear on every CYCLONE® result screen.
Selector two
Which VAULT® fits your project?
Lives on the VAULT® page and goes deeper: it names a stocked size — Giga, Mega, Medium or
Small — confirms that a non-stocked size is one RPH builds, or collects a full specification
for the custom team. Solid lines are the main path; dashed lines are the conditions that send
a project to Custom.
Question Outcome Main path Routes to custom
Pre-engineered is now silent, not removed. RPH no longer promotes the tier,
but the 28 sizes still exist — they have moved into a design log the sales team uses as
preselected sizes, and none have been added since 2025. So the dimension match still runs. A
hit on one of those sizes simply reports that RPH can build it and hands off to the team,
without naming a tier. Nothing is lost but the label.
The two sizing paths exist because the published data supports them differently. Exit Seals™
capacity is given per penetrant diameter for the four stocked sizes only. So a visitor who
knows their line count can be sized into a stocked unit, but reaching a non-stocked size
requires knowing the dimensions.
Selector two · sizing rules
How line count maps to a VAULT® size
These bands come straight from the Exit Seals™ capacity table on the AW | AWI data sheet.
This is the part most worth checking line by line.
Penetrant capacity, lines per unit
Largest OD
Small
Medium
Mega
Giga
Beyond
1.9"
6
8
28
40
Custom
4.5"
—
1
8–11
16
Custom
6.5"
—
—
8
9
Custom
Over 8.625"
—
—
Variable
Variable
Custom
The prototype uses the low end of Mega’s published 8–11 range at 4.5" OD. It always prefers a
stocked size when both a stocked and a non-stocked size fit, since the stocked unit ships
immediately. Anything over 8.625" OD, or ductwork, skips the count question entirely.
What sends a project to Custom
Condition
Where it happens
Penetrants over 8.625" OD, or ductwork
Diameter question
Line count above the largest published capacity
Count question
No size accommodates the entered dimensions
Dimension entry
Curb height other than 14", 18" or 24"
Curb height question
AWI requested at 14" — not an offered combination
Curb height question
The custom intake form uses RPH’s own Custom Penetration Solutions question set —
penetration types, total count, roof or wall placement, diameters, spacing tolerances, roof
slope and unique conditions, Exit Seal OD sizes, and required lead time — plus contact details.
Everything the visitor already answered is carried forward so nothing is asked twice.
Selector three
Which ENTRYPORT™ fits your project?
This one is shaped differently, because the product is. The ENTRYPORT™ Wall Guard has two
outcomes rather than three — a stocked size or a custom build — and only two stocked sizes, so
there is no reason to ask a visitor for dimensions. The Wall Guard is also the only
released product in the line, so ceiling and below-grade applications are told so honestly
rather than pushed toward a product that does not fit them.
Question Outcome Main path Routes to the team
The middle step is not a question but a schedule builder. Because the RPH Exit Seals™ submittal
form is a complete lookup — penetrant family, nominal size, outside diameter and part number —
the selector can accept a real penetrant schedule and hand back the exact seal part numbers
alongside the size recommendation. Three lines of 3/4" Copper ACR come back as seal 5070,
5000 series. For a specifier assembling a submittal, that is the difference between a marketing
widget and a tool they will use twice.
Selector three · sizing rules
How the schedule maps to a Wall Guard
The seal series is derived from the part number, and the series determines capacity. These
counts come from the sample layout panel printed on the submittal and data sheets.
RPH Exit Seals™ series and published Wall Guard capacity
Series
Penetrant OD
Published capacity
Construction
5000
0.25" – 1.9"
Up to 5
Aluminum body, threaded connection
6000
2.125" – 3.125"
Up to 2
Stainless steel flange
7000
3.5" – 4.5"
One
Stainless steel flange
10000
5" and above
Not offered
Stainless steel flange
The lookup behind the schedule builder holds 57 penetrant sizes across five families — Copper
ACR, Copper K&L, Steel Schedule 40, Electrical EMT, and Rigid / Aluminum / Liquid-Tight /
PVC 40 & 80 — taken from the V6 June 2026 submittal form.
What sends a project to Custom
Condition
Where it happens
Any penetrant needing a 10000-series seal, 5" OD or larger
Schedule builder
Wall thickness or interstitial space needing non-standard depth
Conditions question
Penetrant temperatures outside −65°F to 450°F
Conditions question
Ductwork or other non-round penetrants
Conditions question
A finish other than white powder coat
Conditions question
Ceiling or below-grade application
Application question
The ENTRYPORT™ Wall Guard is a sealing device, not a protection device: it consolidates
penetrations through one opening but is not evaluated for missile impact or pressure loading.
Where storm shelter protection is needed it is used together with the CYCLONE® Wall Shroud,
which the main selector now states explicitly.
The custom intake mirrors the Custom ENTRYPORT™ Wall Guard submittal — project name and
number, city and state, required size — plus the project team block from the Exit Seals
submittal, which asks for architect, engineer and GC/MEP contractor. The penetrant schedule
and any special conditions are carried through automatically, so the visitor only fills the
gaps.
Open questions
What we still need from RPH engineering
Each of these is currently handled with a conservative default, so all three prototypes work
today. Most are small changes once answered. The first ENTRYPORT™ item is the only one that
genuinely limits what its selector can do.
Main selector
The review call confirmed the product list is exhaustive, the question count is about right,
and product photography should stay out of the question steps — visitors using this tool
generally do not know the products by sight. Because the CYCLONE® sub-products are each
getting their own page, this selector can route straight to them and no separate CYCLONE®
selector is needed. What remains:
Final wording for the sanitary vent option.
Currently “venting for lavatories, urinals or water closets,” with the result stating the
product is not for equipment exhaust, high heat or high velocity. Confirm this reads
correctly to a plumbing engineer.
Do the wall products have penetrant-type restrictions?
The roof branch asks what is passing through before anything else, because square duct and
louvers settle the choice outright. The wall branch has no equivalent rule. If one wall
product accepts something the other cannot, that question should be added.
Smoke vent, when it releases.
It sits under the drain-or-vent goal rather than becoming a fifth goal, which means that
branch gains a sub-question asking what is being exhausted — sanitary venting to the CVTR,
smoke to the new product. Built as a commented hook, ready to switch on.
Does FEMA funding always mean ICC 500 and FEMA P-361?
The selector treats a FEMA-funded building as pointing to the CYCLONE® line, in the same
answer as storm shelter criteria. If that mapping is not always true, it needs its own
question.
VAULT®
How should a mixed-diameter bundle be sized?
The capacity table assumes a single diameter throughout, but most real projects mix them.
Right now a mixed run still returns a size, marked provisional, with “confirm with our team”
as the primary action. If there is a derating rule we can apply it; if not, mixed runs can
route straight to the team.
In the size tables, is H the housing height or the overall height including curb?
Curb heights of 14", 18" and 24" are treated as a separate spec from the L × W × H
dimensions. If H is actually overall height, the dimension matching needs to account for
curb height before comparing.
Can the four stocked Standard sizes ship with sloped curbs?
The sell sheet confirms sloped and not-sloped for the pre-engineered portfolio but says
nothing about the stocked units. If slope is available across the board we can add it as a
question; if it is pre-engineered and custom only, slope becomes another route to Custom.
ENTRYPORT™
Which standard size does the published seal layout describe, and are the three
series counts additive or alternative?
The sample layout gives up to five 5000-series, up to two 6000-series, and one 7000-series
seal — but never says whether that describes the 10" × 17" unit or the 24" × 36", and never
says whether a single unit can hold five plus two plus one or whether those are three
separate maximum layouts. Without this the selector cannot reliably choose between the two
standard sizes. It currently assumes the layout describes the smaller unit, treats anything
exceeding it as the larger unit marked provisional, and flags any mixed-series schedule for
confirmation. This is the highest-value answer on the list.
What is the model code for the 24" × 36" unit?
The data sheet names Standard WV 1017 and CUSTOM. The larger standard size has no code in
any of the collateral, so the selector currently shows it as pending.
What wall thickness and assembly depth does the standard Wall Guard accommodate?
The data sheet claims compatibility with varying wall thicknesses and interstitial spaces,
but publishes only height and length — no depth dimension or range. Until there is one, any
non-standard depth is treated as a route to Custom, which may be sending work to the custom
team that a standard unit could have handled.
Are there penetrant types the Wall Guard should refuse outright?
The sell sheet lists ductwork as an ideal application, but every Exit Seal in the submittal
form is round and tops out at 4.5" OD within the Wall Guard layout. The selector currently
routes ductwork to Custom. Confirm that is right, or tell us what the duct path looks like.
One discrepancy still worth resolving in the collateral.
The earlier GIGA configuration-count issue is now moot: it only mattered while the catalog was
described publicly as three standard sizes plus 28 pre-engineered. With the pre-engineered
tier off the public material, that count does not appear. One internal point remains — the
data sheet’s testing section groups GIGA with the non-stocked units as FEA-verified rather
than third-party tested, which is worth confirming since GIGA is a stocked size.
The live item is the ENTRYPORT™ warranty. Exhibit A gives the ENTRYPORT™ series a two-year limited
warranty, and the sell sheet repeats it. The same sell sheet then says the RPH Exit Seals™
inside the Wall Guard are backed by twenty years, while also stating the seals are not sold
separately and are fully integrated into the system. A specifier will ask which figure governs
the assembly, and the selector needs to state one of them on the result screen.
One item for the content team, not engineering.
Two removals for the downloads library. The brick lug downspout is no longer sold, but a
“CYCLONE® Brick Lug Downspout Submittal” is still listed. And with the pre-engineered tier no
longer promoted, the Pre-Engineered VAULT® sell sheet should come down alongside it. Both
touch the downloads page and possibly the product pages, so they belong on the Master Tracker
with the other live issues.
Separately, the ENTRYPORT™ submittal PDFs still read “Standard ENTRYPORT™ WALL GUARD.” Under
the Core Designs naming those are being rewritten; worth tracking so the site and the
submittals go live saying the same thing.
Every result screen carries the source document’s own caveat. For VAULT®, that product ratings
do not replace project-specific engineering analysis and final selections must be verified by
the project engineer. For ENTRYPORT™, that seal part numbers should be checked against the
Exit Seals™ submittal form before release, and that bundled materials must be sleeved or
separated to maintain sealing performance.